High Accuracy Digital Peak Voltmeter / Peak Voltage Tester 0 ~ 600 V RMS Signal Range

WUHAN FANKE HAIWO HIGH VOLTAGE TECHNOLOGY CO.,LTD.
Contact Now

High Accuracy Digital Peak Voltmeter / Peak Voltage Tester 0 ~ 600 V RMS Signal Range

Brand Name : Fanke High-voltage

Model Number : YXY-09

Certification : ISO9001

Place of Origin : China

MOQ : One Set

Price : Negotiable

Payment Terms : T/T

Supply Ability : 20 sets /month

Delivery Time : 10~15 working days

Packaging Details : Export standard wooden case with fumigation free

Usage : AC or DC high voltage peak value measuring and display

Applied for : HV measurement for Power frequency AC hipot test set

Display : High accuracy digital LCD display

Accuracy : <1.0%+3

Signal Range : 0 ~ 600 V RMS

Ratio setting : 1~9999

Working frequency : 0-400Hz

Contact Now

Digital AC or DC Peak Voltage Meter With High Accuracy , Matched With Power Frequency Hipot Test

I. Product Introduction

YXY-09 AC / DC peak voltage meter, a new type of intelligent instrument, is designed to meet high voltage requirements. With a large screen, high brightness LCD display, full Chinese menu and operation tips that can achieve a friendly man-machine dialogue. This instrument uses imported TRMS / DC converter module, can be used to accurately measure the true RMS voltage, AC voltage peak, peak / 2, and the average DC voltage.

II. Matched with test system for HV measurement

  • 0-400Hz AC Hipot test
  • Power frequency AC hipot test set
  • DC hipot test set

III. Technical index:

Measuring range 0~9999.9kV (external voltage divider) Impedance input ≥10MΩ
Measuring frequency 0~400Hz Relative humidity < 90%
Measuring error

<1.0%+3

(operating temperature: 20℃±3℃),Linearity error <0.5%

Out-of-limit voltage setting 1~9999kV
Displayed range 0.1~9999.9 Power voltage 220V±10% 50Hz
Ratio setting 1~9999 Power consumption < 10W
Max. voltage input without voltage divider 600V (virtual value) Ambient temperature 0~40℃(error 0.6‰ /℃)
Displayed method LCD

IV. Configuration:

  • Instruction manual 1 copy
  • Certificate of quality 1 copy
  • Power line 1 piece
  • Fuse 2 pieces


Product Tags:

multi range voltmeter

      

peak voltage tester

      
China High Accuracy Digital Peak Voltmeter / Peak Voltage Tester 0 ~ 600 V RMS Signal Range wholesale

High Accuracy Digital Peak Voltmeter / Peak Voltage Tester 0 ~ 600 V RMS Signal Range Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: WUHAN FANKE HAIWO HIGH VOLTAGE TECHNOLOGY CO.,LTD.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0